Related Experiment Video
Updated: Oct 8, 2025

A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
Toe Pressure Measurements in Patients Suspected of Critical Limb Ischemia
Loubna Dari1,2, Damien Barcat3, Benjamin Ally3
1Vascular Medicine Department, 36836Bordeaux University Hospital, Bordeaux, France.
Abstract:
An objective hemodynamic assessment is mandatory to confirm Critical Limb Ischemia (CLI). Toe pressure measurement is recommended. We compared toe measurements obtained using the Laser Doppler method (LD) (PERIMED PeriFlux, Sweden) considered as the reference test, with those obtained with a portable device using photoplethysmography (PPG) (Sys Toe Atys Medical, France). A total of 93 (123 legs) patients from 3 French hospitals with a clinical suspicion of CLI were included and had measurements with each device carried out by skilled operators. PPG was unable to provide a measurement in 10 patients. Lin's Coefficient correlation concordance (CCC) and Bland and Altman's scatter plot were analyzed for the 83 remaining patients, CCC was .84 95%CI (.77-.89). For detection of CLI, Cohen's kappa was .67 95%CI (.53-.81). The PPG device is fairly reliable for toe pressure measurement in patients suspected of CLI and could be useful when LD is not available. However, it fails to deliver a measurement in approximately 10% of cases. No conclusion should be made about CLI for these patients when no measurement is obtainable and other methods should be used (LD, transcutaneous oxygen pressure) to assess perfusion of the limbs.
More Related Videos
07:25Predicting Amputation using Local Circulating Mononuclear Progenitor Cells in Angioplasty-treated Patients with Critical Limb Ischemia
Published on: September 22, 2020
08:16High-Resolution Three-Dimensional Imaging of the Footpad Vasculature in a Murine Hindlimb Gangrene Model
Published on: March 16, 2022
Related Concept Videos
Assessing Blood pressure in the Leg
Preparation:
Pulse Assessment Sites
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure