Cost-Effectiveness Analysis of an Advanced Hybrid Closed-Loop Insulin Delivery System in People with Type 1 Diabetes
Vaia Lambadiari1, Asli Zeynep Ozdemir Saltik2, Simona de Portu2
1Second Department of Internal Medicine, Research Institute and Diabetes Center, Attikon University Hospital, National and Kapodistrian University of Athens, Medical School, Athens, Greece.
Abstract:
Abstract Usage of automated insulin delivery systems is increasing for the treatment of people with type 1 diabetes (T1D). This study compared long-term cost-effectiveness of the Advanced Hybrid Closed Loop MiniMed 780G (AHCL) system versus sensor augmented pump (SAP) system with predictive low glucose management (PLGM) or multiple daily injections (MDI) plus intermittently scanned continuous glucose monitoring (isCGM) in people with T1D in Greece. Analyses were performed using the IQVIA CORE Diabetes Model, with clinical input data sourced from various studies. In the AHCL versus SAP plus PLGM analysis, patients were assumed to have 7.5% baseline glycated hemoglobin (HbA1c), when comparing AHCL with MDI plus isCGM baseline HbA1c was assumed to be 7.8%. HbA1c was reduced to 7.0% following AHCL treatment initiation but remained at baseline levels in the comparator arms. Analyses were performed from a societal perspective over a lifetime time horizon. Future costs and clinical outcomes were discounted at 1.5% per annum. AHCL was associated with increased quality-adjusted life expectancy of 0.284 quality-adjusted life years (QALYs) and EUR 10,173 lower mean total lifetime costs with SAP plus PLGM. Compared with MDI plus isCGM, AHCL was associated with increased quality-adjusted life expectancy of 2.708 QALYs, EUR 76,396 higher mean total lifetime costs, and an incremental cost-effectiveness ratio of EUR 29,869 per QALY. Extensive sensitivity analysis confirmed the robustness of results. Over patient lifetime, the MiniMed 780G system is likely to be cost saving compared with the SAP plus PLGM system and cost-effective compared with MDI plus isCGM in people with T1D in Greece.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes Mellitus: Type 2 and Gestational
Insulin: Biosynthesis, Chemistry, and Preparation
Damage or functional impairment of β-cells inhibits insulin production, leading to diabetes. Diabetes treatment...