Related Experiment Video
Updated: Oct 8, 2025

An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes
Published on: December 25, 2021
Assessment of Radiological Hazard of Radioactive Waste Using Effective or Organ Doses: How This May Affect Final
V K Ivanov, S Yu Chekin1, A V Lopatkin
1A. Tsyb Medical Radiological Research Center, branch of NMRRC of Ministry of Health, Russian Federation, Obninsk.
Abstract:
The radiological hazard of spent nuclear fuel and radioactive waste slows down further development of nuclear energy systems. The authors evaluate timescales required to reduce the radiological hazard of accumulated waste to the reference level of natural uranium that had been consumed by the nuclear energy system. The estimate of this time scale depends on the radiological hazard metric used in the calculations. In this study, two metrics are compared: (1) the committed effective dose based on ICRP Publication 72 and (2) the lifetime radiation risk calculated with use of organ doses and recent radiation risk models recommended by ICRP. The effective dose of the waste reaches the reference level 300 y after the accumulation of waste, while lifetime attributable risk of waste converges to natural uranium in 100 y. Thus, the lifetime attributable risk (LAR) metric is more appropriate to estimate the time requirements for radioactive waste storage and disposal. The effective dose metric significantly overestimates this timescale as it is not intended for quantifying radiation-related risks.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
06:21Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Mutagenicity and Carcinogenicity
Isotopes and Radioisotopes
An isotope containing...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...