Related Experiment Video
Updated: Oct 8, 2025

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Semi-quantitative assessment of ischemia with rubidium-82 PET myocardial perfusion imaging
N M Borren1,2, T J Gerritse1, J P Ottervanger3
1Department of Nuclear Medicine, Isala, Zwolle, The Netherlands.
Purpose:
Semi-quantitative scores can be used as an adjunct to visual assessment in rubidium-82 positron emission tomography (82Rb PET). The semi-quantitative cut-off values used in 82Rb PET are derived from single-photon emission computed tomography (SPECT). It is unknown whether these cut-off values can be extrapolated to 82Rb PET. We compared the semi-quantitative with the visual assessment of ischemia and determined which summed difference score (SDS) score predicts ischemia best.
Methods:
We included 108 patients who underwent 82Rb PET imaging and performed visual and semi-quantitative assessment. A scan with a SDS ≥ 2 and a summed stress score (SSS) ≥ 4 was considered to demonstrate ischemia. We compared the semi-quantitative with the visual assessment.
Results:
41 (38%) Normal scans, and 67 (62%) scans with ischemia and/or an irreversible defect were included. The semi-quantitative assessment showed ischemia more often than the visual assessment (51% vs 29%, P < .001). Patients with a low or intermediate pre-test probability of coronary artery disease (CAD) and a SDS < 4 did not demonstrate ischemia by visual assessment.
Conclusion:
Semi-quantitative assessment in 82Rb PET imaging clearly demonstrates the presence of ischemia. Ischemia is unlikely in patients with low and intermediate pre-test probability of CAD and a SDS < 4.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...