Two-versus three-screw osteosynthesis of the mandibular condylar head: A finite element analysis
Daphne Schönegg1, Günter T Müller1, Michael Blumer1
1Department of Oral and Maxillofacial Surgery, University Hospital of Zurich, Head of Department ad interim: PD Dr. med. Dr. med. dent. Harald Essig, Frauenklinikstrasse 24, CH-8091 Zurich, Switzerland.
Abstract:
Titanium screws are commonly used for osteosynthesis of mandibular condylar head fractures. Evidence suggests that the insertion of three screws may result in better fracture stability. Two screws only, on the other hand, could reduce adverse effects, mainly bone resorption. This study aimed to investigate the biomechanical differences in mandibular condylar head osteosynthesis with two versus three titanium screws using finite element analysis. A finite element model of the mandible with a right type P condylar head fracture fixed with two or three titanium screws was analyzed in ANSYS Mechanical. The geometry of the model assembly was constructed in ANSYS Spaceclaim. Biomechanical load boundary conditions were obtained from a validated musculoskeletal model in AnyBody Modeling System™. The preprocessing of the finite element model and mapping of the obtained boundary conditions was done in docq VIT. Fracture displacement, fragment deformation, von Mises stress distribution, and reaction forces within the screws were evaluated in ANSYS for three different loading scenarios. Finite element analysis showed similar results when comparing osteosynthesis with two versus three titanium screws for all three loading scenarios. Contralateral molar loading resulted in the highest stress on both the fracture and the screws with the maximum von Mises stress being found at the condylar neck. Stress concentration within the screws was found in the fracture gap and was higher in the lateral fragment. In all scenarios, maximum von Mises stress values were smaller when forces were distributed among three screws. However, stability was also adequate when two screws were used. Mandibular condylar head osteosynthesis with two titanium screws appears to provide sufficient fracture stability. Further clinical studies are needed to clarify the implications of these results.
Related Concept Videos
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Three Force Member
For example, consider a dumpster connected to a pin support at point A and a pin attached to a hydraulic cylinder at point B.
Eccentric Axial Loading in a Plane of Symmetry
Support Reactions in Three Dimensions
Ball and Socket Joint is one of the supports allowing free rotation about any axis. This freedom of rotation is...
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Screw: Problem Solving
To evaluate the...