Inadequacy of Augmentation Index for Monitoring Arterial Stiffness: Comparison with Arterial Compliance and Other
Mehmet Kaya1, Vignesh Balasubramanian2, John K-J Li3
1Department of Biomedical and Chemical Engineering and Sciences, Florida Institute of Technology, 150 W University Blvd, Melbourne, FL, 32901, USA. mkaya@fit.edu.
Purpose:
Augmentation Index (AIx) is used clinically for monitoring both wave reflections and arterial stiffness, which when increased is a risk factor of cardiovascular mortality and morbidity. We hypothesize that AIx is not solely related to vascular stiffness as described by arterial compliance and other hemodynamic parameters since AIx underestimates wave reflections.
Methods:
Aortic pressure and flow datasets (n = 42) from mongrel dogs were obtained from our experiments and Mendeley Data under various conditions. Arterial compliances based on the Windkessel model (Ct), the stroke volume (SV) to pulse pressure (PP) ratio (Cv = SV/PP), and at inflection pressure point (CPi) were computed. Other relevant hemodynamic factors are also computed.
Results:
AIx was poorly associated with arterial stiffness calculated from Ct (r = 0.299, p = 0.058) or CPi (r = 0.203, p = 0.203), even when adjusted for heart rates. Ct and Cv were monotonically associated. Alterations in inflection pressure (Pi) did not follow the changes in pulse pressure (PP) (r = 0.475, p = 0.002), and Pi was quantitatively similar to systolic pressure (r = 0.940, p < 0.001).
Conclusion:
AIx is neither linearly correlated with arterial stiffness, nor with arterial compliance and several cardiac and arterial parameters have to be considered when AIx is calculated.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure