Related Experiment Video
Updated: Oct 4, 2025

Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018
Dual detection high-speed capillary electrophoresis for simultaneous serum protein analysis and immunoassays
Prabhavie M Opallage1, Miyuru De Silva1, Robert C Dunn2
1Ralph N. Adams Institute for Bioanalytical Chemistry, Department of Chemistry, University of Kansas, 2030 Becker Drive, Lawrence, KS, 66047, USA.
Abstract:
Serum protein electrophoresis (SPE) separates serum proteins into bands whose shape and amplitude can alert clinicians to a range of disorders. This is followed by more specific immunoassays to quantify important antigens and confirm a diagnosis. Here we develop a high-speed capillary electrophoresis (HSCE) platform capable of simultaneous SPE and immunoassay measurements. A single laser excitation source is focused into the detection zone of the capillary to measure both refractive index (SPE) and fluorescence signals (immunoassays). The refractive index signal measures characteristic SPE profiles for human serum separated in 100 mM boric acid (pH 10), 100 mM arginine (pH 11), and 20 mM CHES (pH 10). For the immunoassay, the fluorescence electropherograms reveal that CHES provides the optimal buffer for measuring the immunocomplex and separating it from the free antigen. Immunoassays in CHES yield a LOD of 23 nM and a LOQ of 70 nM for the detection of fluorescein. The high pH reduces protein adsorption but reduces antibody affinity. Preliminary studies carried out in 50 mM barbital at pH 8 show improved stability of the immunocomplex and better separation for immunoassay quantification. Further optimization will open new capabilities for measuring orthogonal diagnostic signals in seconds with HSCE.
More Related Videos
09:32Procedure and Key Optimization Strategies for an Automated Capillary Electrophoretic-based Immunoassay Method
Published on: September 10, 2017
05:25Author Spotlight: Expanding the Scope of Multiplex Immunoassays for Lyme Borreliosis Diagnostics and Pathogen Research
Published on: July 14, 2023
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...