Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
Clinical concordance assessment should be an integral component of laboratory method comparison studies: A regression
Tejas Kalaria1, Jonathan Fenn1, Anna Sanders2
1New Cross Hospital, Black Country Pathology Services, The Royal Wolverhampton NHS Trust, Wolverhampton WV10 0QP, UK.
Abstract:
Manufacturer-provided assay-specific reference intervals may not compensate for between assay differences leading to method related clinical discordance. Not all laboratories, however, assess clinical concordance as part of method comparison studies. We assessed the utility of method comparison data combined with routine clinical data to assess method related clinical concordance in the diagnosis and management of subclinical hypothyroidism (SCH). Passing-Bablok method comparison regression analysis was performed for both thyroid stimulating hormone (TSH) and free thyroxine (fT4) from 100 samples analysed by Abbott and Roche methods. Primary care samples indicative of SCH were identified from the laboratory information system (LIMS) of two laboratories (one with Roche methods and one with Abbott) over four months. For Roche and Abbott TSH and fT4 results, the Passing-Bablok regression equations were used to predict Abbott and Roche results respectively. The predicted results were interpreted using manufacturer-provided assay-specific reference intervals and compared to those of the previous SCH sample exchange study. On laboratory method comparison, Roche TSH and fT4 results were 30 ± 13% and 16 ± 7% higher compared to Abbott assays respectively. Of those with results indicative of SCH by Roche assays, 76.8% would have had normal thyroid function using predicted Abbott assay results and 46.9% of those with results indicative of SCH by Abbott assays would have had a biochemical indication for levothyroxine replacement using predicted Roche assay results. The results from the regression-based approach were comparable to the previous SCH sample exchange study. A regression-based approach using routine method comparison data and real-world clinical data identifies potential clinical discordance. We suggest that clinical concordance assessment be an integral component of laboratory method comparison studies.
More Related Videos
07:25In Vitro Methods for Comparing Target Binding and CDC Induction Between Therapeutic Antibodies: Applications in Biosimilarity Analysis
Published on: May 4, 2017
06:22Standardization of Transfer across Labs between Flow Cytometers for Detection of Lymphocytes in Japanese Encephalitis Vaccinated Children
Published on: February 10, 2023
Related Concept Videos
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Data Validation
Key parameters for method validation include:
Correlation of Experimental Data
For example, a spherical particle moving through a viscous fluid experiences drag. Dimensional analysis shows that the drag force depends on the particle's diameter, velocity,...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Kendall's Coefficient of Concordance
Calibration Curves: Correlation Coefficient