Refractive changes during off-the-axis retinoscopy in myopia
1Department of Optometry, Sanjivni Eye and Medicare Centre, Ambala, Haryana, India.
Indian Journal of Ophthalmology
|February 28, 2022
Summary
Off-axis retinoscopy in myopic patients shows increased refractive error with greater eccentricity. This study found significant myopic shifts at 10° and 20° off-axis, highlighting potential inaccuracies in ocular examinations.
Area of Science:
- Ophthalmology
- Optometry
- Refractive Error Analysis
Background:
- Retinoscopy is a common method for determining refractive error.
- Off-axis measurements may introduce variability in refractive assessment.
- Understanding these variations is crucial for accurate ocular examinations.
Purpose of the Study:
- To investigate the refractive shift during off-axis retinoscopy in myopic patients.
- To quantify the impact of cycloplegic drugs on these measurements.
- To analyze the accuracy of retinoscopy at different eccentricities.
Main Methods:
- Prospective cross-sectional study involving 10 myopic patients with refractive errors ≤ -3.00 D.
- Cycloplegic refraction performed at 0°, 10°, and 20° by a single examiner.
- Statistical analysis using descriptive data and paired t-test for on-axis vs. off-axis comparisons.
Main Results:
- A mean myopic shift of approximately 7% at 10° and 18% at 20° eccentricity was observed.
- Mean spherical equivalent refractions were -2.5495 D (0°), -2.737 D (10°), and -3.0265 D (20°).
- Statistically significant differences (P < 0.05) were found between on-axis and off-axis measurements.
Conclusions:
- Increased eccentricity during retinoscopy induces greater errors in refractive assessment.
- Off-axis measurements can lead to an overestimation of myopia.
- Clinical practice should consider the impact of retinoscopy angle on refractive outcomes.
Related Concept Videos
Focusing of Light in the Eye
3.3K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
3.3K
Open Angle Glaucoma: Treatment
731
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
731
Angle Closure Glaucoma: Treatment
864
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
864
Glaucoma: Overview
938
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
938