Controlled Microfluidic Environment for Dynamic Investigation of Red Blood Cell Aggregation
Published on: June 4, 2015
Sequential quantification of blood and diluent using red cell sedimentation-based separation and pressure-induced
1Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju, Republic of Korea. yjkang2011@chosun.ac.kr.
Abstract:
The erythrocyte sedimentation method has been widely used to detect inflammatory diseases. However, this conventional method still has several drawbacks, such as a large blood volume (∼1 mL) and difficulty in continuous monitoring. Most importantly, image-based methods cannot quantify RBC-rich blood (blood) and RBC-free blood (diluent) simultaneously. In this study, instead of visualizing interface movement in the blood syringe, a simple method is proposed to quantify blood and diluent in microfluidic channels sequentially. The hematocrit was set to 25% to enhance RBC sedimentation and form two layers (blood and diluent) in the blood syringe. An air cavity (∼300 μL) inside the blood syringe was secured to completely remove dead volumes (∼200 μL) in fluidic paths (syringe needle and tubing). Thus, a small blood volume (Vb = 50 μL) suctioned into the blood syringe is sufficient for supplying blood and diluent in the blood channel sequentially. The relative ratio of blood resident time (RBC-to-diluent separation) was quantified using λb, which was obtained by quantifying the image intensity of blood flow. After the junction pressure (Pj) and blood volume (V) were obtained by analyzing the interface in the coflowing channel, the averaged work (Wp [Pa mm3]) was calculated and adopted to detect blood and diluent, respectively. The proposed method was then applied with various concentrations of dextran solution to detect aggregation-elevated blood. The Wp of blood and diluent exhibited substantial differences with respect to dextran solutions ranging from Cdex = 10 to Cdex = 40 mg mL-1. Moreover, λb did not exhibit substantial differences in blood with Cdex > 10 mg mL-1. The variations in λb were comparable to those of the previous method based on interface movement in the blood syringe. In conclusion, the WP could detect blood as well as diluents more effectively than λb. Furthermore, the proposed method substantially reduced the blood volume from 1 mL to 50 μL.
More Related Videos
11:32A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
Published on: November 23, 2015
09:45Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
Published on: February 4, 2011