Related Experiment Video
Updated: Oct 1, 2025

Author Spotlight: Enhancing Grasping Abilities for Hemiplegic Patients with Flexible Robotic Limbs
Published on: October 27, 2023
Hap-pulse: A Wearable Vibrotactile Glove for Medical Pulse Wave Rendering
Abstract:
Pulse palpation is an important procedure that allows a physician to rapidly assess the status of a patient's cardiovascular system. This paper explores the possibility of using vibrotactile stimuli to render fine temporal profiles of pulse pressure waves. A lightweight wearable vibrotactile glove, called Hap-pulse, is designed to render fine pulse waves through vibrotactile stimuli on users' fingertips. To preserve the fine features of original pulse waves, models are fitted from real pulse wave data (photoplethysmogram (PPG) pulse waveform database), using fourth-order polynomial functions. A square wave envelope mapping algorithm is proposed to produce vibration amplitudes of Linear Resonance Actuators (LRAs), which aims to render the detailed waveform of systolic and diastolic blood pressure states. Evaluation results suggest that Hap-pulse can render pulse waves with an average correlation coefficient 97.84%. To validate the distinguishability and fidelity of Hap-pulse's palpation rendering, a user study consisting of traditional Chinese medicine doctors and unskilled students is conducted. The correct recognition rate of identifying four typical pulse waves is 87.08% (doctors), 57.50% (untrained students) and 79.59% (trained students). These results indicate a novel application of rendering subtle pulse wave signals with vibrotactile gloves, which illustrates the potential of simulating patient palpation training in virtual or remote medical diagnosis.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse Assessment Sites
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...