Background:
Although described in product monographs, the maximum contrast media (CM) dose at computed tomography (CT) varies among institutions.
Purpose:
To investigate whether an upper limit of 40 g of iodine in women and 50 g in men is sufficient or if there is a body weight (BW) dependence of mean hepatic enhancement (MHE) beyond those thresholds.
Material And Methods:
At our institution, CM injection duration is fixed to 30 s and dosed 600 mg iodine/kg up to 40 g in women and 50 g in men. Pre- and post-contrast hepatic attenuation values (HU) were retrospectively obtained in 200 women and 200 men with glomerular filtration rate >45 mL/min undergoing 18-flurodeoxyglucose PET-CT (18F-FDG PET-CT) of which half weighed below and half above those dose thresholds using iodixanol 320 mg iodine/mL or iomeprol 400 mg iodine/mL. The correlation between BW and MHE was assessed by simple linear regression.
Results:
Weight range was 41-120 kg in women and 47-137 kg in men. There was no significant relationship between MHE and BW in women receiving <40 g (r = -0.05, P = 0.63) or in men receiving <50 g (r = 0.18, P = 0.07). Above those thresholds there was an inverse relationship (r = -0.64, P<0.001 in women and r = -0.30, P<0.002 in men). There was no apparent upper limit where the dependence of hepatic MHE on BW decreased. Hepatosteatosis limited MHE.
Conclusion:
Adjusting CM to BW diminishes the dependence of MHE on BW. There was no apparent upper limit for the relationship between BW and MHE in heavier patients at CM-enhanced CT.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
06:52Positron Emission Tomography Using 64-Copper as a Tracer for the Study of Copper-Related Disorders
Published on: April 28, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Hepatic Drug Excretion: Influencing Factors
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...