Clinical use of magnetic resonance imaging in buttock augmentation with silicone implants: a retrospective analysis
Jiaqi Zhang1, Chau Loon Wong1, Jian Zhang1
1Department of Plastic Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China.
Background:
The objective of the current study was to retrospectively examine the morphological magnetic resonance imaging (MRI) characteristics of the gluteus maximus of buttock augmentation at levels of predetermined anatomic points.
Methods:
The present study was a retrospective cross-sectional study. Adult women who underwent high-quality MRI scanning at Sun Yat-sen Memorial Hospital of Sun Yat-sen University from January 2018 to January 2021 were included in this work. The transverse MRI data measured at the inferior point of the sacroiliac joint, just above the femoral head, and at the ischial tuberosity were collected and statistically analyzed.
Results:
Fifty-two cases (104 sides of female gluteus maximus) were included in the final analysis. The A point (surgery starting point) were 54.4±6.34 mm, 54.91±5.57 mm, and 73.91±5.57 mm away from the posterior midline at the level of inferior point of the sacroiliac joint, just above the femoral head, and at the ischial tuberosity, respectively. Accordingly, the thickness of the muscle at these locations was 16.0±4.17 mm, 23.4±4.40 mm, and 24.6±7.58 mm, respectively. The diameter of the implant did not exceed 14.18±1.22 cm. In addition, the gluteus maximus at the lowest point of the sacroiliac joint and above the femoral head exhibited an arc structure, which needs to be tilted to the deep plane during separation.
Conclusions:
Dissimilar from previous experience of blind dissection, the gluteus maximus muscle can be more scientifically and reasonably dissected using the indexes for gluteus augmentation supplied in this study.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI