Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Comprehensive two-dimensional gas chromatography using direct flow modulation to extend the secondary dimension
Huamin Cai1, Stanley D Stearns1
1Valco Instruments Co. Inc.
Abstract:
A simple direct flow modulator has been constructed and evaluated. This modulator employs a tee to connect the primary and secondary columns so that a negative pulsed flow can be introduced through the third leg of the connector into the joint between the columns. The modulation gas pressure can be adjusted to allow a longer recovery time for the primary column flow after the reversal initiated at the beginning of a modulation period, resulting in a longer secondary separation time. In this study, a 120 s secondary separation time has been achieved. That is long enough for use with a longer secondary column and secondary temperature ramping. Factors which affect the secondary peak width at base (2Wb), including modulation pulse width, modulation period, and inlet/modulation pressure differential, have also been investigated. Our results indicate that all three of these factors have a large impact on 2Wb, since they all affect the amount of primary effluent loaded onto the secondary dimension. Various sizes of tee connectors - 360 µm, 1/32″, and 1/16″ - have been investigated as well. Out of those three, the 360 µm tee gives the best performance in terms of less peak tailing and narrower 2Wb. The time needed to switch from one dimension GC to GC×GC for this method is discussed, and several methods to shorten the waiting time have been proposed. Applications of this method on gasoline and reference gas oil standard have been demonstrated.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II