Related Experiment Video
Updated: Sep 29, 2025

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Transcatheter Aortic Valve Replacement with the Self-Expandable Core Valve Evolut Prosthesis Using the Cusp-Overlap
Philipp Maximilian Doldi1,2, Lukas Stolz1, Felix Escher3
1Medizinische Klinik und Poliklinik I, Klinikum der Universität München, 81377 Munich, Germany.
Abstract:
Despite the rapid increase in experience and technological improvement, the incidence of conduction disturbances in patients undergoing transcatheter aortic valve replacement (TAVR) with the self-expandable CoreValve Evolut valve remains high. Recently, a cusp-overlap view (COP) implantation technique has been proposed for TAVR with self-expandable valves offering an improved visualization during valve expansion compared to the three-cusp view (TCV). This study aims to systematically analyze procedural outcomes of TAVR patients treated with the CoreValve Evolut valve using a COP compared to TCV in a high-volume center. The primary endpoint was technical success according the 2021 VARC-3 criteria. A total of 122 consecutive patients (61 pts. TCV: April 2019 to November 2020; 61 pts. COP: December 2020 to October 2021) that underwent TAVR with the CoreValve Evolut prosthesis were included in this analysis. Although there was no difference in the primary endpoint technical success between TCV and COP patients (93.4% vs. 90.2%, OR 0.65, 95% CI 0.16, 2.4, p = 0.51), we observed a significantly lower risk for permanent pacemaker implantation (PPI) among COP patients (TCV: 27.9% vs. COP: 13.1%, OR 0.39, 95% CI 0.15, 0.97, p = 0.047). Implantation of the CoreValve Evolut prosthesis using the COP might help to reduce the rate of PPI following TAVR.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Cardiac Catheterization I: Pre-Procedure Overview