Related Experiment Video
Updated: Sep 28, 2025

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
COVID-19 Oximetry @home: evaluation of patient outcomes
Michael Boniface1, Daniel Burns1, Christopher Duckworth2
1IT Innovation Centre, School of Engineering and Computer Science, University of Southampton, Southampton, UK.
Background:
COVID-19 has placed unprecedented demands on hospitals. A clinical service, COVID-19 Oximetry @home (CO@h) was launched in November 2020 to support remote monitoring of COVID-19 patients in the community. Remote monitoring through CO@h aims to identify early patient deterioration and provide timely escalation for cases of silent hypoxia, while reducing the burden on secondary care.
Methods:
We conducted a retrospective service evaluation of COVID-19 patients onboarded to CO@h from November 2020 to March 2021 in the North Hampshire (UK) community led service (a collaboration of 15 General Practitioner (GP) practices covering 230 000 people). We have compared outcomes for patients admitted to Basingstoke and North Hampshire Hospital who were CO@h patients (COVID-19 patients with home monitoring of oxygen saturation (SpO2; n=115), with non-CO@h patients (those directly admitted without being monitored by CO@h (n=633)). Crude and adjusted OR analysis was performed to evaluate the effects of CO@h on patient outcomes of 30-day mortality, Intensive care unit (ICU) admission and hospital length of stay greater than 3, 7, 14 and 28 days.
Results:
Adjusted ORs for CO@h show an association with a reduction for several adverse patient outcome: 30-day hospital mortality (p<0.001, OR 0.21, 95% CI 0.08 to 0.47), hospital length of stay larger than 3 days (p<0.05, OR 0.62, 95% CI 0.39 to 1.00), 7 days (p<0.001, OR 0.35, 95% CI 0.22 to 0.54), 14 days (p<0.001, OR 0.22 95% CI, 0.11 to 0.41), and 28 days (p<0.05, OR 0.21, 95% CI 0.05 to 0.59). No significant reduction ICU admission was observed (p>0.05, OR 0.43, 95% CI 0.15 to 1.04). Within 30 days of hospital admission, there were no hospital readmissions for those on the CO@h service as opposed to 8.7% readmissions for those not on the service.
Conclusions:
We have demonstrated a significant association between CO@h and better patient outcomes; most notably a reduction in the odds of hospital lengths of stays longer than 7, 14 and 28 days and 30-day hospital mortality.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...