Related Experiment Video
Updated: Sep 28, 2025

Author Spotlight: Magnetometric Characterization of Intermediates in the Solid-State Electrochemistry of Redox-Active Metal-Organic Frameworks
Published on: June 9, 2023
A novel flow injection amperometric method for sensitive determination of total antioxidant capacity at
Selen Ayaz1, Ayşem Üzer2, Yusuf Dilgin3
1Department of Chemistry, Faculty of Art and Science, Çanakkale Onsekiz Mart University, 17100, Çanakkale, Turkey.
Abstract:
A novel amperometric method is presented for the determination of total antioxidant capacity in flow injection analysis (FIA) system using copper(II)-neocuproine complex modified on Nafion-functionalized multi-walled carbon nanotube-glassy carbon electrode ([Cu(Ncp)22+]/Nf@f-MWCNT/GCE). Cyclic voltammetric studies showed that the modified electrode exhibits a very well-formed reversible redox couple for Cu(II)-/Cu(I)-complex. In addition, the [Cu(Ncp)22+]/[Cu(Ncp)2+] redox pair shows very good electrocatalytic activity towards the oxidation of polyphenolic compounds (PPhCs) such as trolox, catechin, and quercetin due to the enhancement of the anodic peak current of the redox couple in the presence of these analytes. This electrocatalytic oxidation current at the [Cu(Ncp)22+]/Nf@f-MWCNT/GCE was used for flow injection (FI) amperometric determination of PPhCs. FI amperometric-time curves recorded under optimized conditions (applied potential: + 0.6 V vs. Ag/AgCl/KCl(0.10 M), flow rate: 2 mL/min) showed that the proposed electrode had a wide linear range (LR) with a very low detection limit (LOD) for PPhCs. LR and LOD were 0.5-800 and 0.2 µM for trolox, respectively and 0.50-250 and 0.14 µM, respectively, for both quercetin and catechin. This sensitive method was successfully applied to the amperometric measurement of total antioxidant capacity (TAC) of some herbal teas, giving compatible results with the spectrophotometric CUPRAC method. The proposed method gave higher rank to fast-reacting antioxidants; it was equally precise but had a wider linear range and lower LOD than the spectrophotometric CUPRAC assay (e.g., LOD for ascorbic acid and gallic acid were 0.07 and 0.08 μM, respectively), and similar electroanalytical methods using the CUPRAC reagent.
More Related Videos
Related Concept Videos
Amperometry: Overview
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Controlled-Current Coulometry: Overview
Voltammetric Techniques: Cyclic Voltammetry

