Related Experiment Video
Updated: Sep 28, 2025

Acquisition and Semi-Automated Analysis of Respiratory Muscle Surface Electromyography
Published on: January 24, 2025
The coming era of a new auscultation system for analyzing respiratory sounds
Yoonjoo Kim1, YunKyong Hyon2, Sunju Lee2
1Division of Pulmonology and Critical Care Medicine, Department of Internal Medicine, College of Medicine, Chungnam National University, Daejeon, 34134, Korea.
Abstract:
Auscultation with stethoscope has been an essential tool for diagnosing the patients with respiratory disease. Although auscultation is non-invasive, rapid, and inexpensive, it has intrinsic limitations such as inter-listener variability and subjectivity, and the examination must be performed face-to-face. Conventional stethoscope could not record the respiratory sounds, so it was impossible to share the sounds. Recent innovative digital stethoscopes have overcome the limitations and enabled clinicians to store and share the sounds for education and discussion. In particular, the recordable stethoscope made it possible to analyze breathing sounds using artificial intelligence, especially based on neural network. Deep learning-based analysis with an automatic feature extractor and convoluted neural network classifier has been applied for the accurate analysis of respiratory sounds. In addition, the current advances in battery technology, embedded processors with low power consumption, and integrated sensors make possible the development of wearable and wireless stethoscopes, which can help to examine patients living in areas of a shortage of doctors or those who need isolation. There are still challenges to overcome, such as the analysis of complex and mixed respiratory sounds and noise filtering, but continuous research and technological development will facilitate the transition to a new era of a wearable and smart stethoscope.
Related Concept Videos
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...

