Critical Factors of Dose Distribution in Breast Cancer Tomotherapy With Metallic Port Breast Tissue Expander: Image
Hsing-Yi Lee1, Yu-Hsiu Yen2,3, Yu-Lun Tsai4,5
1Department of Radiation Oncology, Oncology Treatment Center, 124851Sijhih Cathay General Hospital, New Taipei City, Taiwan.
Abstract:
Objectives: Breast reconstruction helps patients enhance their body image after mastectomy. Metallic ports in tissue expanders lead to dose attenuation during radiotherapy. Tissue expander volume shifts the metallic port position, possibly causing various dose alterations. This study aimed to evaluate the impact of the MAGNA-SITETM tissue expander volume on tomotherapy. Methods: Boluses and MAGNA-SITETM were placed on a Rando phantom to simulate the tissue expander under the pectoralis major. Computed tomography simulation images were transformed through replacing the electron density of (a) metallic artifact region only (Image metallic port) and (b) metallic port and artifact regions (Image Homo). Planning was calculated using fixed-beam and helical-mode techniques. Radiation was delivered with different volumes of the tissue expander. Results: Integrated 997 dose points were calculated. Planning with Image metallic port provided a calculated dose significantly closer to a realistic dose. The percentage of doses achieving the prescribed dose was significantly higher in the helical mode. In layer 2, the 100-mL tissue expander had a significantly lower measurement dose than all other volumes. Volume 150 mL had the highest increase in the measured dose difference from the plan dose at layer 2. Volume 250 mL had the highest percentage of measurement doses passing the 5% dose difference from plan dose. The coldest dose areas were noted in layers 1 and 2, especially in the metallic port-direct image mode. The average dose reduction of the measured cold areas was 6.03 ± 1.94%. Conclusion: Dose distribution was affected by the volume of the metallic port tissue expander. Tomotherapy with proper image heterogeneity correction and helical mode can reduce the attenuation from the metallic port. A tissue expander volume of 150 to 250 mL is suitable. Patients with high risk at the chest wall should be evaluated carefully to avoid underdosing. Radiation oncologists should closely cooperate with plastic surgeons to optimize treatment for each patient.
More Related Videos
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022