Shorter weighing phase durations in force plate analyses introduce small errors in average force, but these accumulate, significantly impacting kinetic and kinematic metrics. Longer durations are needed for reliable force plate data.
Area of Science:
- Biomechanics
- Sports Science
- Human Movement Analysis
Background:
- Force plate analysis is crucial for evaluating athletic performance and movement.
- Accurate calculation of kinetic, temporal, and kinematic metrics relies on defining the force plate's weighing phase (WP).
- The impact of varying weighing phase durations on data reliability remains under-investigated.
Purpose of the Study:
- To investigate the effect of different weighing phase durations on the agreement of vertical force-time variables.
- To assess the repeatability of average force (WPav) and standard deviation of force (WPsd) across varying durations.
- To determine optimal weighing phase durations for accurate force plate analysis.
Main Methods:
- Compared weighing phase durations of 0.5, 1.0, and 1.5 seconds against a 2.0-second reference.
- Calculated limits of agreement (LOA) for system weight, onset threshold, onset time, net impulse, take-off velocity, and displacement.
- Assessed WPav and WPsd repeatability using repeatability coefficients across 137 jumps (counter-movement, squat, single leg).
Main Results:
- Shorter durations yielded minimal WPav differences (< ±0.25%) but led to significant accumulated errors in net impulse (±2%) and take-off displacement (±23%).
- Using 5xWPsd as an onset threshold resulted in substantial differences (±25% to ±72%) and affected onset time (±6% to ±18%).
- WPav demonstrated high repeatability, but integration effects necessitate WPs longer than 2.0 seconds; WPsd showed poor repeatability.
Conclusions:
- Weighing phase duration significantly influences the accuracy of integrated force-time variables in jump analysis.
- A weighing phase duration longer than 2.0 seconds is recommended for reliable force plate data, especially when using onset thresholds.