Reliability of Repeated Isometric Neck Strength in Rugby Union Players Using a Load Cell Device
Christian Chavarro-Nieto1, Martyn Beaven1, Nicholas Gill1,2
1Division of Health, Engineering, Computing and Science, Te Huataki Waiora School of Health, University of Waikato, Adams Centre for High Performance, Tauranga 3116, New Zealand.
Abstract:
Concussion is the most common injury in professional Rugby Union (RU) players, with increasing incidence and severity each year. Strengthening the neck is an intervention used to decrease concussion incidence and severity, which can only be proven effective if strength neck measures are reliable. We conducted a repeated-measures reliability study with 23 male RU players. Neck strength was assessed seated in a ‘make’ test fashion in flexion, extension, and bilateral-side flexion. Flexion-to-extension and left-to-right side ratios were also computed. Three testing sessions were undertaken over three consecutive weeks. Intrasession and intersession reliabilities were assessed using typical errors, coefficient of variations (CV), and intraclass correlation coefficients (ICC). Intrasession reliability demonstrated good-to-excellent relative (ICC > 0.75) and good absolute (CV ≤ 20%) reliability in all directions (ICC = 0.86−0.95, CV = 6.4−8.8%), whereas intersession reliability showed fair relative (ICC: 0.40 to 0.75) and acceptable absolute (CV ≤ 20%) reliability for mean and maximal values (ICC = 0.51−0.69, CV = 14.5−19.8%). Intrasession reliability for flexion-to-extension ratio was good (relative, ICC = 0.86) and acceptable (absolute, CV = 11.5%) and was fair (relative, ICC = 0.75) and acceptable (absolute, CV = 11.5%) for left-to-right ratio. Intersession ratios from mean and maximal values were fair (relative, ICC = 0.52−0.55) but not always acceptable (absolute, CV = 16.8−24%). Assessing isometric neck strength with a head harness and a cable with a load cell device seated in semi-professional RU players is feasible and demonstrates good-to-excellent intrasession and fair intersession reliability. We provide data from RU players to inform practice and assist standardisation of testing methods.
More Related Videos
10:07Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
06:52An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020