Related Experiment Video
Updated: Sep 25, 2025

Generation and Control of Electrohydrodynamic Flows in Aqueous Electrolyte Solutions
Published on: September 7, 2018
Electrophoresis of a highly charged fluid droplet in dilute electrolyte solutions: Analytical Hückel-type solution
Meng-Yu Tsai1, Leia Fan1, Jessica Tseng1
1Department of Chemical Engineering, National Taiwan University, Taipei, Taiwan.
Abstract:
An analytical formula is presented here for the electrophoresis of a dielectric or perfectly conducting fluid droplet with arbitrary surface potentials suspended in a very dilute electrolyte solution. In other words, when the Debye length (κ-1 ) is very large, or κa 1, where κ is the electrolyte strength and a stands for the droplet radius. This formula can be regarded as an extension of the famous Hückel solution valid for weakly charged rigid particles to arbitrarily charged fluid droplets. The formula reduces successfully to the ones obtained by Booth for a dielectric droplet, and Ohshima for a perfectly conducting droplet, both under Debye-Hückel approximation valid for weakly charged droplets. Moreover, the formula is valid for a gas bubble and a rigid solid particle as well. Classic results obtained by Hückel for a rigid particle are reproduced as well. We found that for a dielectric droplet, the more viscous the droplet is, the faster it moves regardless of its surface potential, contrary to the intuition based on the purely hydrodynamic consideration. For a perfectly conducting liquid droplet, on the other hand, the situation is reversed: The less viscous the droplet is, the faster it moves. The presence or absence of the spinning electric driving force tangent to the droplet surface is found to be responsible for it. As a result, an axisymmetric exterior vortex flow surrounding the droplet is always present for a dielectric liquid droplet, and never there for a conducting liquid droplet.
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Capillary Electrophoresis: Instrumentation
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...

