Related Experiment Video
Updated: Sep 25, 2025

Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Left Brachiocephalic Perforation During Right Heart Catheterization
Samid M Farooqui1, Justin North2, Roberto J Bernardo1
1Division of Pulmonary, Critical Care and Sleep Medicine, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA.
Abstract:
Right heart catheterization is overall considered a safe procedure, although complications can arise from venous access injuries, arrhythmias, vasovagal episodes, and pulmonary artery rupture. We present a case of left brachiocephalic vein perforation during a diagnostic right heart catheterization, which was managed conservatively. (Level of Difficulty: Beginner.).
More Related Videos
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
Cardiac Catheterization I: Pre-Procedure Overview
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations: