Introduction:
The use of high-flow cannula therapy (HFNC) in neonatal units has increased in recent years, but there are no consensus guidelines on its indications and application strategies. Our aim was to know the rate of use of HFNC, their indications and the management variability among Spanish neonatal units.
Material And Methods:
Twenty-five-question survey for medical and nursing staff. Level II and III units were contacted by phone and sent in Google forms between September 2016 and December 2018.
Results:
Ninety-seven responses (63.9% medical, 36.1% nursing), from 69 neonatal units representing 15 autonomous communities (87% level of care III; 13% level II). All units except one have HFNC with a humidified and heated system. Their most frequent indications are: non-invasive ventilation weaning (79.4%), bronchiolitis (69.1%), respiratory distress of the term newborn (58.8%), after extubation (50.5%). Minimum flow (1-5 L/min) and maximum flow (5-15 L/min) are variable between units. 22.7% have experienced some adverse effect from its use (9 air leak, 12 nasal trauma). Less than half have an employment protocol, but all the answers agree on the usefulness of national recommendations.
Conclusions:
HFNC therapy is widely used in Spanish units, but there is great variability in its indications and strategies of use. National recommendations would be applicable in most units and would allow unifying its use.
More Related Videos
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Suctioning the Nasopharyngeal Airway
Equipment Required
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Cardiopulmonary Resuscitation II: ACLS Airway Management