Advanced Fault-Tolerant Anti-Surge Control System of Centrifugal Compressors for Sensor and Actuator Faults
Turki Alsuwian1, Arslan Ahmed Amin2, Muhammad Taimoor Maqsood2
1Department of Electrical Engineering, College of Engineering, Najran University, Najran 11001, Saudi Arabia.
Abstract:
Faults frequently occur in the sensors and actuators of process machines to cause shutdown and process interruption, thereby creating costly production loss. centrifugal compressors (CCs) are the most used equipment in process industries such as oil and gas, petrochemicals, and fertilizers. A compressor control system called an anti-surge control (ASC) system based on many critical sensors and actuators is used for the safe operation of CCs. In this paper, an advanced active fault-tolerant control system (AFTCS) has been proposed for sensor and actuator faults of the anti-surge control system of a centrifugal compressor. The AFTCS has been built with a dedicated fault detection and isolation (FDI) unit to detect and isolate the faulty part as well as replace the faulty value with the virtual redundant value from the observer model running in parallel with the other healthy sensors. The analytical redundancy is developed from the mathematical modeling of the sensors to provide estimated values to the controller in case the actual sensor fails. Dual hardware redundancy has been proposed for the anti-surge valve (ASV). The simulation results of the proposed Fault-tolerant control (FTC) for the ASC system in the experimentally validated CC HYSYS model reveal that the system continued to operate in the event of faults in the sensors and actuators maintaining system stability. The proposed FTC for the ASC system is novel in the literature and significant for the process industries to design a highly reliable compressor control system that would continue operation despite faults in the sensors and actuators, hence preventing costly production loss.
Related Concept Videos
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Directional Relays
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Distribution Reliability and Automation
Load-frequency control