Related Experiment Video
Updated: Sep 20, 2025

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
Computed Tomography Image Features under Denoising Algorithm for Benign and Malignant Diagnosis of Renal Parenchymal
1Department of Urology, Qilu Hospital (Qingdao), Shandong University, Qingdao 266035, Shandong, China.
Abstract:
To improve the quality of computed tomography (CT) images and provide help for benign and malignant diagnosis of renal parenchymal tumors, the independent component analysis (ICA) denoising algorithm was used. An improved ICA X-ray CT (X-CT) medical image denoising algorithm was proposed. ICA provided a higher signal-to-noise ratio for CT image denoising. Forty patients with renal tumor were selected as the observation group. The CT image performance of patients was evaluated by the denoising algorithm and compared with the wavelet transform algorithm, and the peak signal-to-noise ratio of the proposed algorithm was analyzed and compared. The results showed that among the 40 patients with renal tumors, 12 were renal clear cell carcinoma cases and 28 were cystic renal carcinoma cases. The accuracy of the enhanced CT image was 93.8%, and that of the CT image using the denoising algorithm was 96.3%; the difference between the two was significant (P < 0.05). The peak signal-to-noise ratio (PSNR) of the algorithm proposed was higher than the PSNR values of CT and noisy images. The PSNR of the proposed algorithm was significantly higher than that of mean filtering. The root mean square error (RMSE) algorithm of the proposed algorithm was significantly lower than that of the mean algorithm in image data processing (P < 0.05), which showed the superiority of the proposed algorithm. Enhanced CT can be staged significantly. In conclusion, the algorithm had a significant effect on the edge contour of detailed features, and the accuracy of CT images based on intelligent calculation was significantly higher than that of conventional CT images for benign and malignant renal parenchyma tumors, which was worth promoting in clinical diagnosis.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies VII: Vascular Imaging
Imaging Studies IV: Magnetic Resonance Imaging

