Error Detectability of Isodose Volumes as ROIs in Prostate Intensity-modulated RT QA
Ryuta Nakahara1,2, Masayuki Fujiwara3, Haruyuki Takaki1
1Department of Radiology, Hyogo Medical University, Nishinomiya, Japan.
Background/Aim:
To evaluate the quality of error detectability with a three-dimensional verification system using isodose volumes as regions of interest (ROIs) in quality assurance (QA) of intensity-modulated radiation therapy.
Patients And Methods:
Treatment plans with four types of intentional errors were created from the data of 20 patients with localized prostate cancer. These plans underwent QA using the three-dimensional verification system. The datasets of another 30 cases without inserted errors were assessed as controls. The ROIs used in the evaluations were those used in our conventional method (planning target volume, rectum, and bladder). The isodose volume method (5%, 50% and 95% isodose volume) and the error detection rates (measurement above the tolerance values, as set from the other 30 cases) were assessed and compared.
Results:
There was significantly higher multileaf collimator systematic closed error detectability with the isodose volume method compared to the conventional method (A-side 0.2 mm: p=0.005, A-side 0.35 mm: p=0.002, B-side 0.2 mm: p=0.001 and B-side 0.35 mm: p=0.010). There were no error types for which the error detection rate of the isodose volume method was lower than that of the conventional method.
Conclusion:
The isodose volume method was able to evaluate the irradiated ROIs that could be delineated, and improved error detectability. This method has the potential to provide a wider margin of safety in intensity-modulated radiation therapy.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
08:05Detection and Isolation of Cancer in Prostate Biopsies Using Stimulated Raman Histology and Artificial Intelligence
Published on: June 10, 2025
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
