SYS-FLASH. Systemic saturation in FLASH MR imaging.

D Matthaei, A Haase

    Magnetic Resonance in Medicine
    |March 1, 1987
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    The impact of lipid distribution, composition and mobility on xylem water refilling of the resurrection plant Myrothamnus flabellifolia.

    The New phytologist·2021
    Same author

    A bridged loop gap resonator (BLGR) for small animal imaging by 1.5 T MRI systems.

    The Review of scientific instruments·2020
    Same author

    Insights into possibilities for grouping and read-across for nanomaterials in EU chemicals legislation.

    Nanotoxicology·2018
    Same author

    Minute Impurities Contribute Significantly to Olfactory Receptor Ligand Studies: Tales from Testing the Vibration Theory.

    eNeuro·2017
    Same author

    Analysis of 2D NMR relaxation data using Chisholm approximations.

    Journal of magnetic resonance (San Diego, Calif. : 1997)·2017
    Same author

    A simple metal staining procedure for identification and visualization of single cells by LA-ICP-MS.

    The Analyst·2017
    Same journal

    Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging.

    Magnetic resonance in medicine·2026
    Same journal

    A Simple, Dynamic Geometric Phantom for MRI and CT Reconstruction Pipelines: Beyond Shepp-Logan.

    Magnetic resonance in medicine·2026
    Same journal

    7T 3D-EPI PCASL With High SNR Efficiency and Robustness to Through-Plane B<sub>0</sub> Field Gradients.

    Magnetic resonance in medicine·2026
    Same journal

    A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

    Magnetic resonance in medicine·2026
    Same journal

    Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

    Magnetic resonance in medicine·2026
    Same journal

    Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

    Magnetic resonance in medicine·2026
    See all related articles

    A new technique called Systemic Saturation FLASH (SYS-FLASH) modifies Fast Low Angle SHot (FLASH) MR imaging. This method effectively reduces blood flow intensity and artifacts in transaxial images.

    Area of Science:

    • Medical Imaging
    • Magnetic Resonance Imaging
    • Biomedical Engineering

    Background:

    • Fast Low Angle SHot (FLASH) Magnetic Resonance (MR) imaging is susceptible to flow artifacts.
    • Flowing blood can significantly alter image intensity and diagnostic accuracy in transaxial tomograms.

    Purpose of the Study:

    • To introduce a simple modification to FLASH MR imaging to reduce blood flow signals and artifacts.
    • To present a novel technique, SYstemic Saturation FLASH (SYS-FLASH), for improved image quality.

    Main Methods:

    • A nonselective radiofrequency pulse of variable flip angle was applied before each projection in FLASH imaging.
    • This pulse was used to saturate flowing blood within the entire imaging volume, creating the SYS-FLASH technique.

    Related Experiment Videos

    Main Results:

    • The SYS-FLASH modification resulted in a variable reduction of flowing blood intensity.
    • This technique effectively decreased flow artifacts observed in transaxial tomograms.

    Conclusions:

    • SYS-FLASH is a simple and effective modification for FLASH MR imaging.
    • The technique offers improved image quality by mitigating blood flow artifacts.