Related Experiment Video
Updated: Sep 6, 2025

Mechanical Expansion of Steel Tubing as a Solution to Leaky Wellbores
Published on: November 20, 2014
Optimization of the Structural Performance of Buried Reinforced Concrete Pipelines in Cohesionless Soils
Odey Alshboul1, Ghassan Almasabha1, Ali Shehadeh2
1Department of Civil Engineering, Faculty of Engineering, The Hashemite University, P.O. Box 330127, Zarqa 13133, Jordan.
Abstract:
Pipelines are widely used to transport water, wastewater, and energy products. However, the recently published American Society of Civil Engineers report revealed that the USA drinking water infrastructure is deficient, where 12,000 miles of pipelines have deteriorated. This would require substantial financial investment to rebuild. Furthermore, the current pipeline design practice lacks the guideline to obtain the optimum steel reinforcement and pipeline geometry. Therefore, the current study aimed to fill this gap and help the pipeline designers and practitioners select the most economical reinforced concrete pipelines with optimum steel reinforcement while satisfying the shear stresses demand and serviceability limitations. Experimental testing is considered uneconomical and impractical for measuring the performance of pipelines under a high soil fill depth. Therefore, a parametric study was carried out for reinforced concrete pipes with various diameters buried under soil fill depths using a reliable finite element analysis to execute this investigation. The deflection range of the investigated reinforced concrete pipelines was between 0.5 to 13 mm. This indicates that the finite element analysis carefully selected the pipeline thickness, required flexural steel reinforcement, and concrete crack width while the pipeline does not undergo excessive deformation. This study revealed that the recommended optimum reinforced concrete pipeline diameter-to-thickness ratio, which is highly sensitive to the soil fill depth, is 6.0, 4.6, 4.2, and 3.8 for soil fill depths of 9.1, 12.2, 15.2, and 18.3 m, respectively. Moreover, the parametric study results offered an equation to estimate the optimum pipeline diameter-to-thickness ratio via a design example. The current research outcomes are imperative for decision-makers to accurately evaluate the structural performance of buried reinforced concrete pipelines.
More Related Videos
Related Concept Videos
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Permeability of Concrete
Design Example: Distributing Reinforcements in Concrete Sections
Effects of Creep
Bending of Material: Problem Solving
Multiple Pipe Systems
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...