Related Experiment Video
Updated: Sep 5, 2025

Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification
Published on: August 17, 2015
Relative response factors and multiple regression models in liquid chromatography to quantify low-dosed components
Cedric De Leersnijder1,2, Céline Duchateau1,2, Kris De Braekeleer1
1ULB- Faculty of Pharmacy - RD3 - Pharmacognosy, Bioanalysis and Drug Discovery Unit - Bld Triomphe, Campus Plaine, CP 205/6 - B - 1050, Brussels, Belgium.
Abstract:
A classical quantitative analysis in liquid chromatography is performed using either a one-point calibration or a calibration line, prepared using a reference standard of the compound(s) of interest. However, in some cases, adequate reference standards may be very expensive, rare to obtain, or have limited shelf-life properties. Also, in herbal matrices, multiple compounds could be necessary to be quantified, needing a whole series of different (related) reference standards. In these cases, the use of relative response (sometimes called relative correction factors) factors (RRFs) towards reference standards, different of the compound to be quantified, gained attraction. This study performed a comparison of the use of RRFs and linear relative response factor models (LRRFM) for the quantification of targeted low-dosed compounds using an alternative standard, since it is known that classical RRFs often fail in lower concentration ranges. For this purpose, the determination of the total Δ9-tetrahydrocannabinol (Δ9-THC + Δ9-THC-A) content in dried cannabis flowers, using UHPLC-DAD, was used as a case study. A chromatographic method was implemented and validated, and the use of classical calibration lines, classical RRF, and the LRRFM was applied and compared, with special focus on the concentration around 0.2% (w/w) total Δ9-THC, the legal limit (in most European countries) in these products. Results showed that the newly presented and validated LRRFM approach outperformed the classical RRFs, especially in the low-concentration ranges and that concentrations obtained with the LRRFM were in accordance with the interpolation results obtained with a calibration line.
More Related Videos
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
08:06Absolute Quantification of Cell-Free Protein Synthesis Metabolism by Reversed-Phase Liquid Chromatography-Mass Spectrometry
Published on: October 25, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
High-Performance Liquid Chromatography: Instrumentation