Related Experiment Video
Updated: Sep 5, 2025

2D and 3D Echocardiography in the Axolotl Ambystoma Mexicanum
Published on: November 29, 2018
Anesthesia for Echocardiography and Magnetic Resonance Imaging in the African Clawed Frog (Xenopus laevis)
Antonio F Corno1, Noelia E Flores2, Wen Li3
1Children's Heart Institute, Memorial Hermann Children's Hospital, McGovern Medical School at UTHealth, Houston, Texas;,
Abstract:
This report describes an anesthesia technique that we used to study cardiovascular anatomy and physiology with echocardiography and cardiac magnetic resonance (CMR) in 46 African clawed frogs (Xenopus laevis) (n = 24 for electrocardiography and n = 22 for CMR). For administration of anesthesia, 3 holding tanks, one each for transportation, sedation, and recovery, were filled with filtered water, with 0.05% buffered tricaine methasulfonate solution (MS-222) added into the sedation tank. Fifteen minutes after the frog was placed in the sedation tank, a paper towel was soaked in MS-222 solution, and the frog was placed in a supine position and rolled 3 to 4 times in the soaked paper with the head and legs exposed. Vital signs were monitored and recorded throughout the procedure. After imagining, frogs were unrolled from the paper towel, placed in the recovery tank, and later returned to their home tank. Monitoring was discontinued when the frogs resumed typical activity. No mortality or complications were observed in frogs that underwent this procedure. Mean duration ±1 SD of anesthesia induction was 12 ± 5 min in the echocardiography group and 14 ± 6 min in the CMR group. The mean duration of anesthesia maintenance was 60 ± 18 min in the echocardiography group and 118 ± 37 min in the CMR group. An additional dose of anesthesia was necessary during maintenance for 9 of 24 (37%) frogs in the echocardiography group and 6 of 22 (27%) frogs in the CMR group. At the end of the procedure, the mean oxygen saturation was 66 ± 9% in the echocardiography group and 85 ± 6% in the CMR group, and heart rate was 48 ± 13 beats/min in the echocardiography group and 42 ± 7 beats/min in the CMR group. We conclude that the anesthesia technique of immersion in MS-222 is suitable for performing echocardiography and CMR imaging in this species without complications.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System V: CT

