Accuracy of a 3D temporal scanning system for gait analysis: Comparative with a marker-based photogrammetry system
Ana V Ruescas Nicolau1, Helios De Rosario1, Fermín Basso Della-Vedova1
1Instituto de Biomecánica de Valencia, Universitat Politècnica de València, edifici 9C. Camí de Vera, s/n, 46022 València, Spain.
Gait & Posture
|July 22, 2022
Summary
3D temporal scanners offer a markerless gait analysis solution comparable in accuracy to marker-based stereophotogrammetry. This technology provides a viable alternative for human movement analysis, overcoming limitations of traditional marker systems.
Area of Science:
- Biomechanics
- Motion Analysis
- Medical Imaging
Background:
- Marker-based stereophotogrammetry offers high accuracy but is cumbersome.
- Markerless human movement analysis lacks the desired precision.
- 3D temporal scanners present a potential solution by providing detailed 3D mesh data.
Purpose of the Study:
- To evaluate if 3D temporal scanners can achieve markerless gait analysis accuracy comparable to marker-based stereophotogrammetry.
- To compare the precision of 3D temporal scanners against traditional motion capture systems.
Main Methods:
- A comparative study synchronized a 3D temporal scanner with a marker-based stereophotogrammetry system.
- Analyzed two gait cycles of twelve healthy adults, extracting 3D kinematics of the pelvis and lower limb joints.
- Quantified measurement differences using root mean square, t-tests, and F-tests.
Main Results:
- Differences in 3D landmark positions were 1.9–2.4 mm in the reference pose.
- Marker position errors increased significantly in medial-lateral and vertical directions during motion.
- Relative angle errors ranged from 3% to 43%, with hip axial rotation showing the largest discrepancy.
Conclusions:
- 3D temporal scanners achieve accuracy comparable to marker-based systems, with differences smaller than soft-tissue artifacts and manual marker placement errors.
- The accuracy surpasses other markerless systems, establishing 3D temporal scanners as a strong alternative for motion capture.
- This technology enhances usability and comfort in human movement analysis.