Related Experiment Video
Updated: Sep 3, 2025

In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
Biological Variation in Rotational Thromboelastometry in Patients with Atrial Fibrillation Receiving Rivaroxaban
Mojca Božič Mijovski1,2, Jovan P Antovic3,4, Rickard E Malmström5,6
1Department of Vascular Diseases, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia.
Rotational thromboelastometry (ROTEM) is a viscoelastic hemostasis test used primarily in the management of bleeding after trauma or in cardiac surgery. To allow safe and valid clinical interpretation of test results, objective specifications for analytical performance are needed, which are generally based on biological variation within (CVI) and between (CVG) individuals. The aim of this study was to evaluate biological variation in ROTEM in patients receiving rivaroxaban. Sixty patients with atrial fibrillation on stable rivaroxaban therapy were included, from whom blood was collected on six occasions: three times at trough and three at peak rivaroxaban concentrations. ROTEM® Extem and LowTF were measured as well as rivaroxaban concentration, PT, APTT, and anti-Xa. Within- (CVI) and between-subject (CVG) biological estimates were calculated. Knowledge of these biological variation components will help to establish the appropriate objective analytical performance specifications for ROTEM analysis.
Rotational thromboelastometry (ROTEM) is a viscoelastic hemostasis test used primarily in the management of bleeding after trauma or in cardiac surgery. To allow safe and valid clinical interpretation of test results, objective specifications for analytical performance are needed, which are generally based on biological variation within (CVI) and between (CVG) individuals. The aim of this study was to evaluate biological variation in ROTEM in patients receiving rivaroxaban. Sixty patients with atrial fibrillation on stable rivaroxaban therapy were included, from whom blood was collected on six occasions: three times at trough and three at peak rivaroxaban concentrations. ROTEM® Extem and LowTF were measured as well as rivaroxaban concentration, PT, APTT, and anti-Xa. Within- (CVI) and between-subject (CVG) biological estimates were calculated. Knowledge of these biological variation components will help to establish the appropriate objective analytical performance specifications for ROTEM analysis.
Related Concept Videos
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Venous Thrombosis III: Interprofessional Care
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies

