Preparation and Evaluation Mechanic Damping Properties of Fused Silica Powder@Polyurethane Urea/Cement Composites
Hao Cheng1, Peihui Yan1,2, Fei Wan1
1School of Civil Engineering, Qingdao University of Technology, Qingdao 266033, China.
Abstract:
In this paper, cement based on fused silica powder @ polyurethane urea (FSP@PUU) with a micro constrained damping structure was studied. Firstly, FSP@PUU core-shell particles were prepared by heterogeneous stepwise addition polymerization method and added into cement paste as damping filler to form a micro-constrained damping structure inside cement paste. The mechanical property and damping performance of cement-based composites were characterized by compressive strength, dynamic mechanical analysis (DMA) test and modal vibration test. The results showed that the damping performance of FSP @ PUU cement-based composites was affected by temperature, and the loss tangent of cement with 6wt% FSP@PUU increased to about 0.057 at -35 °C to 35 °C, which was 1.5 times cement paste within the glass transition temperature. With 6 wt% FSP@PUU, the damping ratio of cement-based composites increased by 58% compared with cement paste in the frequency range of 175-300 Hz, while the compressive strength decreased by only 5%. The cement with suitable FSP@PUU possesses excellent damping performance.
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Fineness of Cement
Direct...
Soundness of Cement