Simulation and Experiment of Substation Grounding Resistance Measurement Based on Pseudorandom Signal

Qingming Duan1, Bofeng Zou1, Shanshan Li1

  • 1College of Instrumentation & Electrical Engineering, Jilin University, Changchun 130012, China.

Related Concept Videos

Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
142
Wald-Wolfowitz Runs Test II01:17

Wald-Wolfowitz Runs Test II

The Wald-Wolfowitz runs test, commonly referred to as the runs test, is a nonparametric test used to assess the randomness of ordered data. The test evaluates the number of runs, which are consecutive sequences of similar elements within the data. If the number of runs is significantly higher or lower than expected, the data is considered non-random, indicating a detectable pattern or structure.
For binary data, runs are identified using symbols such as + and −, or equivalently, 1s and...
307
Equivalent Resistance01:16

Equivalent Resistance

In circuit analysis, situations often arise where resistors are neither in series nor parallel configurations. To tackle such scenarios, three-terminal equivalent networks like the wye (Y) (Figure 1 (a)) or tee (T) and delta (Δ) (Figure 1 (b)) or pi (π) networks come into play. These networks offer versatile solutions and are frequently encountered in various applications, including three-phase electrical systems, electrical filters, and matching networks.
567
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
220
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
145
Resistance and Conductance01:25

Resistance and Conductance

A conductor's DC resistance at a given temperature is influenced by its resistivity, length, and cross-sectional area. Resistivity is an inherent property of the conductor material, with annealed copper serving as the international standard for measurement. For instance, the resistivity of hard-drawn aluminum at 20 degrees Celsius is 61% of the standard conductivity of annealed copper.
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...
121