Evaluation of Biomaterials for Bladder Augmentation using Cystometric Analyses in Various Rodent Models
Published on: August 9, 2012
[Is pressure transmission quality during cystometry dependent on the type of effort?]
1Sorbonne Université, GRC 01, GREEN Groupe de Recherche Clinique en Neuro-Urologie, AP-HP, Hôpital Tenon, 75020 Paris, France.
Introduction:
The International Continence Society (ICS) recommends a control of the good pressure transmission by a coughing effort during cystometry. While poor transmission is sometimes observed in routine practice, other maneuvers can also be proposed. The main objective of this study was to determine if there is a better maneuver to evaluate the pressure transmission ratio between the abdominal cavity and the bladder.
Methods:
We performed a prospective, consecutive, single-center study in a tertiary neuro-urology department in 31 subjects. During a cystometry, each patient was asked to perform at 0ml and 100ml of bladder filling, a cough effort, an abdominal push and a Valsalva maneuver controlled by a manometer. The value of the bladder pressure to abdominal pressure ratio was collected manually. The average variations were compared between each maneuver for the same volume of replenishment and between the 2 volumes of replenishment studied.
Results:
At 0ml of filling, the difference in pressure variation between the Pves and the Pabd is significantly higher during the cough maneuver compared to the Valsalva (P=0.015), which is not found at 100ml of filling.
Conclusion:
During bladder filling, the pressure transmission ratios during the 3 maneuvers are equivalent. Coughing or abdominal thrusting, which are easier to perform than the Valsalva maneuver, should be recommended to check the quality of the recording during cystomanometry.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Urodynamic Studies: Uroflowmetry
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.