Related Experiment Video
Updated: Sep 1, 2025

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
A deep learning-based whole-body solution for PET/MRI attenuation correction.
Sahar Ahangari1, Anders Beck Olin2, Marianne Kinggård Federspiel2
1Department of Clinical Physiology, Nuclear Medicine, and PET, Rigshospitalet, Copenhagen, Denmark. sahar.ahangari@gmail.com.
Deep learning (DL) for whole-body PET attenuation correction (AC) in PET/MRI generates synthetic CT (sCT) from MRI. This DL-based sCT method offers more accurate PETAC than atlas-based approaches.
Area of Science:
- Medical Imaging
- Artificial Intelligence in Medicine
- Radiology
Background:
- Deep convolutional neural networks show promise for PET attenuation correction (AC) in PET/MRI.
- Whole-body implementation is challenging due to anatomical variations and limited MRI field of view.
Purpose of the Study:
- Investigate a deep learning (DL) method to generate voxel-based synthetic CT (sCT) from Dixon MRI.
- Utilize sCT as a whole-body solution for PET AC in PET/MRI systems.
Main Methods:
- Trained a DL network using co-registered MRI and CT images from 15 patients with whole-body PET/CT and PET/MRI scans.
- Assessed AC map accuracy and PET image quantification using DL-based sCT (PET_sCT) versus an atlas-based method (PET_Atlas), with CT-based reconstruction (PET_CT) as reference.
- Performed voxel-wise and region-specific analyses (brain, lung, liver, spine, bone, aorta).
Main Results:
- DL-based sCT achieved a lower mean absolute error (62 HU) compared to the atlas-based method (109 HU).
- PET_sCT showed excellent correlation with PET_CT (R²=0.98) and lower PET quantification error (6.1%) than PET_Atlas (11.2%).
- PET_sCT demonstrated reduced average errors and variability across all analyzed regions.
Conclusions:
- A DL approach for whole-body PET AC in PET/MRI is feasible and yields more accurate results than conventional methods.
- Further validation with larger training datasets is recommended for enhanced robustness and accuracy.