Denoising using deep-learning-based reconstruction for whole-heart coronary MRA with sub-millimeter isotropic
Toshiya Kariyasu1, Haruhiko Machida1, Sanae Takahashi2
1Department of Radiology, Faculty of Medicine, Kyorin University, Tokyo, Japan; Department of Radiology, Tokyo Women's Medical University Adachi Medical Center, Adachi-ku, Tokyo, Japan.
Abstract:
PURPOSE The aim of this study was to assess the usefulness of denoising deep-learning-based reconstruction (dDLR) to improve image quality and vessel delineation in noncontrast 3-T wholeheart coronary magnetic resonance angiography (WHCMRA) with sub-millimeter isotropic resolution (Sub-mm) compared with a standard resolution without dDLR (Standard). METHODS For 10 healthy volunteers, we acquired the WHCMRA with Sub-mm with and without dDLR and Standard to quantify signal- (SNR) and contrast-to-noise ratio (CNR) and vessel edge signal response (VESR) in all the 3 image types. Two independent readers subjectively graded vessel sharpness and signal homogeneity of 8 coronary segments in each patient. We used Kruskal- Wallis test with Bonferroni correction to compare SNR, CNR, VESR, and the subjective evaluation scores among the 3 image types and weighted kappa test to evaluate inter-reader agreement on the scores. RESULTS SNR was significantly higher with Sub-mm with dDLR (P < .001) and Standard (P=.005) than with Sub-mm without dDLR and was comparable between Sub-mm with dDLR and Standard (P=.511). CNR was significantly higher with Sub-mm with dDLR (P < .001) and Standard (P=.005) than with Sub-mm without dDLR and was comparable between Sub-mm with dDLR and Standard (P=.560). VESR was significantly greater with Sub-mm with (P=.001) and without dDLR (P=.017) than with Standard and was comparable between Sub-mm with and without dDLR (P=1.000). In the proximal, middle, distal, and all the coronary segments, the subjective vessel sharpness was significantly better with Sub-mm with dDLR than Sub-mm without dDLR and Standard (P < .001, for all) and was comparable between Sub-mm without dDLR and Standard (P > .05); the subjective signal homogeneity was significantly improved from Sub-mm without dDLR to Standard to Sub-mm with dDLR (P < .001). The inter-reader agreement was excellent (kappa=0.84). CONCLUSION Application of dDLR is useful for improving image quality and vessel delineation in the WHCMRA with Sub-mm compared with Standard.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging