Related Experiment Video
Updated: Aug 31, 2025

Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Natural Deep Eutectic Solvent-Based Dispersive Liquid-Liquid Microextraction Coupled with Direct Analysis in Real
Meng Chen1, Ming Li2, Wenxi Zhang3
1Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China.
Abstract:
Green analytical chemistry (GAC) represents a rapidly growing research field that aims at developing novel analytical approaches with minimal consumption of hazardous reagents and solvents. The current study reports on a GAC methodology exploiting the unique physicochemical properties of natural deep eutectic solvents (NADESs), a supposedly environmentally friendly class of solvents. Based on a temperature-mediated strategy, the NADESs were manipulated to undergo multiple phase transitions for favorable functionality and performance. As proof-of-concept demonstrations, both hydrophobic and hydrophilic NADESs were prepared for the extraction and analysis of eight phthalate esters in aqueous samples (food simulants) and three aflatoxins in oily samples (edible oils), respectively. NADES-based dispersive liquid-liquid microextraction (DLLME) was employed to achieve high-efficiency sample pretreatment. Afterward, the NADESs were transformed from liquids into solids by tuning the peripheral temperature for a convenient phase separation from the sample matrices. The solidified NADES extracts were melted and vaporized at elevated temperatures by transmission-mode direct analysis in real time (DART) for further quadrupole-Orbitrap high-resolution mass spectrometry (Q-Orbitrap HRMS) analysis. The developed protocol was validated, achieving good repeatability with relative standard deviations (RSDs) of less than 9% and satisfactory sensitivity with limits of detection (LODs) and quantitation (LOQs) ranging from 0.1 to 0.8 and 0.2 to 2.0 μg/kg, respectively. The greenness of the analytical methodology was assessed with the calculated scores of 0.66 and 0.57 for the hydrophobic and hydrophilic NADES-based protocols, respectively. The method was applied to marketed samples, highlighting the great potential for green chemical analysis.
More Related Videos
11:17A Simple Fractionated Extraction Method for the Comprehensive Analysis of Metabolites, Lipids, and Proteins from a Single Sample
Published on: June 1, 2017
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...