Related Experiment Video
Updated: Aug 30, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Doublet Metalens with Simultaneous Chromatic and Monochromatic Correction in the Mid-Infrared
Yi Zhou1,2, Fengyuan Gan1,2, Ruxue Wang1,2
1State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
Abstract:
Metalenses provide a powerful paradigm for mid-infrared (MIR) imaging and detection while keeping the optical system compact. However, the design of MIR metalenses simultaneously correcting chromatic aberration and off-axis monochromatic aberration remains challenging. Here, we propose an MIR doublet metalens composed of a silicon aperture metalens and a silicon focusing metalens separated by a fused silica substrate. By performing ray-tracing optimization and particle-swarm optimization, we optimized the required phase profiles as well as the sizes and spatial distributions of silicon nanopillars of the doublet metalens. Simulation results showed that the MIR doublet metalens simultaneously achieved chromatic and off-axis monochromatic aberration reduction, realizing a continuous 400 nm bandwidth and 20° field-of-view (FOV). Thanks to its planar configuration, this metalens is suitable for integration with CMOS image sensor to achieve MIR imaging and detection, which has potential application in troubleshooting and intelligent inspection of power grids. This work may facilitate the practical application of metalens-integrated micro/nanosensors in intelligent energy.
More Related Videos
08:18High-Accuracy Correction of 3D Chromatic Shifts in the Age of Super-Resolution Biological Imaging Using Chromagnon
Published on: June 16, 2020
16:10A TIRF Microscopy Technique for Real-time, Simultaneous Imaging of the TCR and its Associated Signaling Proteins
Published on: March 22, 2012
Related Concept Videos
IR Spectrometers
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...