Related Experiment Video
Updated: Aug 29, 2025

Precision Measurements and Parametric Models of Vertebral Endplates
Published on: September 17, 2019
An experimental-numerical method for the calibration of finite element models of the lumbar spine
Luis Fernando Nicolini1, Agnes Beckmann2, Markus Laubach3
1Institute of General Mechanics (IAM), RWTH Aachen University, Eilfschornsteinstr. 18, Aachen, 52062, North Rhine-Westphalia, Germany; Department for Trauma and Reconstructive Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, Aachen, 52074, North Rhine-Westphalia, Germany; Mechanical and Analysis Design Group (GRANTE), Federal University of Santa Catarina, R. Lauro Linhares, 1850, Florianópolis, 88070-260, Santa Catarina, Brazil.
Abstract:
We present a systematic and automated stepwise method to calibrate computational models of the spine. For that purpose, a sequential resection study on one lumbar specimen (L2-L5) was performed to obtain the individual contribution of the IVD, the facet joints and the ligaments to the kinematics of the spine. The experimental data was prepared for the calibration procedure in such manner that the FE model could reproduce the average motion of the 10 native spines from former cadaveric studies as well as replicate the proportional change in ROM after removal of a spinal structure obtained in this resection study. A Genetic Algorithm was developed to calibrate the properties of the intervertebral discs and facet joints. The calibration of each ligament was performed by a simple and novel technique that requires only one simulation to obtain its mechanical property. After calibration, the model was capable of reproducing the experimental results in all loading directions and resections.