Related Experiment Video
Updated: Aug 28, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Analysis of Fracture Resistance of Endodontically Treated Teeth with Different Restorative Materials: An In vitro
Abhigyan Manas1, Amit Kumar2, Kranti Sorte Gawali3
1Department of Dentistry, UP University of Medical Sciences, Saifai, Utter Pradesh, India.
Objectives:
The objective of the study is to compare the fracture resistance of endodontic treated tooth restored with GIC, amalgam, and composite cements.
Materials And Methods:
Forty teeth were divided into 4 groups of 10 teeth each. Group I teeth were restored with silver amalgam. Group II teeth were restored with GIC. Group III teeth were restored with composite and Group IV teeth were control in which no alteration was performed. Testing machine applied force on teeth to detect fracture resistance.
Results:
The mean fracture resistance was maximum in Group IV (1050.2 N) followed by Group III (956.2 N), Group I (836.4 N), and Group II (766.4 N). The difference was statistically significant (P < 0.05). The mean difference of fracture resistance was significant (P > 0.05).
Conclusion:
Composite resin possesses highest fractures resistance as compared to GIC and silver amalgam.