High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Rapid Acid/Base Switching in Flow Injection Analysis and Isocratic Elution Liquid Chromatography with Mass
Yu-Jie Huang1, Wei-Chien Tu1, Pawel L Urban1,2
1Department of Chemistry, National Tsing Hua University 101, Section 2, Kuang-Fu Rd, Hsinchu 300044, Taiwan.
Abstract:
Ion signals in electrospray ionization (ESI) mass spectrometry (MS) are affected by addition of acid or base. Acids or bases are typically added to samples to enhance detection of analytes in positive- or negative-ion mode, respectively. To carry out simultaneous monitoring of analytes with different ionogenic moieties by ESI-MS, a rapid acid/base switching system was developed. The system was further coupled with flow injection analysis (FIA) and liquid chromatography (LC) MS. The two variants enable detection of separated analytes immediately after alternating addition of acid and base. The methods were tested using a set of phospholipids (PLs) as analytes. The rapid acid/base switching enhanced signals of some of the PL analytes in both ion modes of MS. Both FIA-MS and LC-MS with acid/base switching show signal enhancements (∼1.3-23.2 times) of some analyte signals when compared with analysis conducted without acid/base switching. The proposed methods are suitable for simultaneous analysis of cationic and anionic analytes. The FIA-MS and LC-MS methods with acid/base switching were also applied in analysis of lipid extract from real samples (sausage and porcine liver). However, the FIA-MS results were affected by ionization competition and isobaric interference due to the complexity of the sample matrix and diversity of PL species. In contrast, the LC-MS mode provides adequate selectivity to observe signal enhancement for specific analyte ions. Overall, alternating addition of acid and base immediately before the ESI source can improve analytical performance without the need to carry out separate analyses targeting different types of analytes.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
10:41Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Types of Detectors
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Instrumentation