Related Experiment Video
Updated: Aug 28, 2025

An Objective and Child-friendly Assessment of Arm Function by Using a 3-D Sensor
Published on: February 12, 2018
Wrist motion assessment using Microsoft Azure Kinect DK: A reliability study in healthy individuals
Aleksandra Królikowska1, Agnieszka Maj2, Maciej Dejnek2,3
1Ergonomics and Biomedical Monitoring Laboratory, Department of Physiotherapy, Faculty of Health Sciences, Wroclaw Medical University, Poland.
New software using Microsoft Azure Kinect Developer Kit (DK) shows high reliability for measuring wrist and forearm range of motion (ROM). This technology offers a promising tool for clinical hand assessments and rehabilitation.
Area of Science:
- Biomedical Engineering
- Rehabilitation Technology
- Motion Analysis
Background:
- Motion analysis systems are crucial in orthopedics and rehabilitation for diagnostics and monitoring.
- The Microsoft Azure Kinect Developer Kit (DK) has potential for clinical applications, but its use in wrist motion assessment is under-explored.
- Standardized, reliable, valid, and responsive examinations for wrist motion remain a challenge.
Purpose of the Study:
- To evaluate the reliability of hand and forearm range of motion (ROM) measurements using novel software with the Microsoft Azure Kinect DK.
- To assess the intra-day and inter-day reliability of the developed system.
Main Methods:
- Twenty-eight males and 28 females underwent active ROM measurements for wrist and forearm movements.
- Measurements were taken on three separate occasions (two sessions same day, one session one week later).
- Data were collected using custom software integrated with the Microsoft Azure Kinect DK, with reliability assessed via intraclass correlation coefficient (ICC).
Main Results:
- The software demonstrated high intra-day and inter-day reliability in both male and female participants.
- The lowest intraclass correlation coefficient (ICC) values for males were 0.846 (intra-day) and 0.816 (inter-day).
- For females, the lowest ICC values were 0.826 (intra-day) and 0.833 (inter-day).
Conclusions:
- The developed software utilizing the Microsoft Azure Kinect DK exhibits high reliability for wrist and forearm active ROM measurements.
- These findings suggest the Microsoft Azure Kinect DK is a viable tool for clinical hand assessments.
- The technology shows potential as an effective tool for hand rehabilitation programs.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
08:45Kinematic Analysis Using 3D Motion Capture of Drinking Task in People With and Without Upper-extremity Impairments
Published on: March 28, 2018