Data Acquisition Protocol for Determining Embedded Sensitivity Functions
Published on: April 20, 2016
Digital sampling of acoustic impulse noise: Implications for exposure measurement and damage risk criteria
Christoper J Smalt1, Douglas S Brungart2
1Human Health & Performance Systems Group, MIT Lincoln Laboratory, Lexington 02421, Massachusetts, USA.
Abstract:
Current standards for the measurement of impulse noise (e.g., MIL-STD-1474E) recommend using a sampling rate of at least 200 kHz in order to accurately estimate the risk of hearing damage. The given motivation for this high sampling rate is to ensure a temporal resolution in the impulse waveform fine enough to accurately capture the peak pressure. However, the Nyquist-Shannon sampling theorem specifies that a sampled signal can accurately reconstruct both the amplitude and phase information of a signal given the sampling rate is at least twice the highest frequency present in the original signal. Thus, it is possible to reconstruct a band limited signal with the same temporal resolution as one captured at a higher sampling rate if the contributions of energy above the Nyquist rate can be ignored. In this study, resampling techniques are applied to a signal sampled at 48 kHz to extract A-weighted sound pressure energy estimates within 0.1 dB of those obtained at a higher sampling rate. Our results suggest sampling rates for impulsive noise should be based on the range of frequencies expected to make a contribution to injury risk rather than on concerns about temporal resolution.
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Sampling Continuous Time Signal
In the...