Related Experiment Video
Updated: Aug 25, 2025

Electrospray Deposition of Uniform Thickness Ge23Sb7S70 and As40S60 Chalcogenide Glass Films
Published on: August 19, 2016
Simulation of the Refractive Index Variation and Validation of the Form Deviation in Precisely Molded Chalcogenide
Cheng Jiang1, Carlos Marin Tovar1, Jan-Helge Staasmeyer1
1Department of Fine Machining and Optics, Fraunhofer Institute for Production Technology IPT, 52074 Aachen, Germany.
Abstract:
Precise infrared (IR) optics are core elements of infrared cameras for thermal imaging and night vision applications and can be manufactured directly or using a replicative process. For instance, precision glass molding (PGM) is a replicative manufacturing method that meets the demand of producing precise and accurate glass optics in a cost-efficient manner. However, several iterations in the PGM process are applied to compensate the induced form deviation and the index drop after molding. The finite element method (FEM) is utilized to simulate the thermomechanical process, predicting the optical properties of molded chalcogenide lenses and thus preventing costly iterations. Prior to FEM modelling, self-developed glass characterization methods for the stress and structure relaxation of chalcogenide glass IRG 26 are implemented. Additionally, a ray-tracing method is developed in this work to calculate the optical path difference (OPD) based on the mesh structure results from the FEM simulation. The developed method is validated and conducted during the production of molded lenses.