Related Experiment Video
Updated: Aug 23, 2025

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
Dose-Volume Constraints fOr oRganS At risk In Radiotherapy (CORSAIR): An "All-in-One" Multicenter-Multidisciplinary
Silvia Bisello1,2, Savino Cilla3, Anna Benini1,2
1Department of Experimental, Diagnostic and Specialty Medicine-DIMES, Alma Mater Studiorum University of Bologna, 40128 Bologna, Italy.
Background:
The safe use of radiotherapy (RT) requires compliance with dose/volume constraints (DVCs) for organs at risk (OaRs). However, the available recommendations are sometimes conflicting and scattered across a number of different documents. Therefore, the aim of this work is to provide, in a single document, practical indications on DVCs for OaRs in external beam RT available in the literature.
Material And Methods:
A multidisciplinary team collected bibliographic information on the anatomical definition of OaRs, on the imaging methods needed for their definition, and on DVCs in general and in specific settings (curative RT of Hodgkin's lymphomas, postoperative RT of breast tumors, curative RT of pediatric cancers, stereotactic ablative RT of ventricular arrythmia). The information provided in terms of DVCs was graded based on levels of evidence.
Results:
Over 650 papers/documents/websites were examined. The search results, together with the levels of evidence, are presented in tabular form.
Conclusions:
A working tool, based on collected guidelines on DVCs in different settings, is provided to help in daily clinical practice of RT departments. This could be a first step for further optimizations.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...