Related Experiment Video
Updated: Aug 23, 2025

Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
Published on: June 20, 2025
Comparison between Chest-Worn Accelerometer and Gyroscope Performance for Heart Rate and Respiratory Rate Monitoring
Chiara Romano1, Emiliano Schena1, Domenico Formica2
1Unit of Measurements and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy.
Abstract:
The demand for wearable devices to simultaneously monitor heart rate (HR) and respiratory rate (RR) values has grown due to the incidence increase in cardiovascular and respiratory diseases. The use of inertial measurement unit (IMU) sensors, embedding both accelerometers and gyroscopes, may ensure a non-intrusive and low-cost monitoring. While both accelerometers and gyroscopes have been assessed independently for both HR and RR monitoring, there lacks a comprehensive comparison between them when used simultaneously. In this study, we used both accelerometers and gyroscopes embedded in a single IMU sensor for the simultaneous monitoring of HR and RR. The following main findings emerged: (i) the accelerometer outperformed the gyroscope in terms of accuracy in both HR and RR estimation; (ii) the window length used to estimate HR and RR values influences the accuracy; and (iii) increasing the length over 25 s does not provide a relevant improvement, but accuracy improves when the subject is seated or lying down, and deteriorates in the standing posture. Our study provides a comprehensive comparison between two promising systems, highlighting their potentiality for real-time cardiorespiratory monitoring. Furthermore, we give new insights into the influence of window length and posture on the systems' performance, which can be useful to spread this approach in clinical settings.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...

