The Cardiac Power Index during Abdominal Open Aortic Surgery: Intraoperative Insights into the Cardiac Performance-A

Fulvio Nisi1, Enrico Giustiniano1, Massimo Meco2

  • 1Department of Anesthesia, Intensive Care Unit and Pain Therapy, IRCCS Humanitas Clinical and Research Center, Via Manzoni 56, 20089 Milan, Italy.

Insights

The Cardiac Power Index (CPI) significantly increases after aortic unclamping during open aortic surgery, indicating its role in monitoring heart function. Lower baseline CPI may predict the need for inotropic support in these patients.

Area of Science:

  • Cardiology
  • Cardiovascular Surgery
  • Hemodynamics

Background:

  • The Cardiac Power Index (CPI) quantifies heart energy output and is linked to cardiogenic shock mortality.
  • Open aortic surgery involves significant hemodynamic shifts due to aortic clamping and unclamping, potentially impairing cardiac function.
  • Understanding these hemodynamic changes is crucial for patient outcomes.

Purpose of the Study:

  • To investigate the impact of aortic cross-clamping (Ao-XC) and unclamping (Ao-UC) on the Cardiac Power Index (CPI) during open aortic surgery.
  • To assess secondary hemodynamic parameters including cardiac index (CI), mean arterial pressure (MAP), heart rate, and lactate levels.
  • To explore the potential of CPI as a real-time indicator of cardiac performance and impairment during surgery.

Main Methods:

  • Retrospective analysis of 67 patients undergoing open surgical aortic repair.
  • Intra-operative hemodynamic monitoring using the EV1000-FloTrac System™.
  • Calculation of CPI as (CI × MAP)/451 and analysis of variations during basal, Ao-XC, and Ao-UC phases.

Main Results:

  • CPI showed a significant increase after aortic unclamping (basal: 0.39 ± 0.1 W/m², after Ao-UC: 0.44 ± 0.2 W/m², p < 0.05).
  • Cardiac index (CI) varied significantly during both clamping and unclamping (p < 0.0001), while MAP and heart rate remained stable.
  • Patients requiring inotropic support post-clamping had a lower baseline CPI (0.31 ± 0.11 W/m²) compared to the general cohort.

Conclusions:

  • CPI effectively reflects cardiac function adaptation to hemodynamic changes during aortic cross-clamping and unclamping.
  • CPI offers a minimally invasive method for real-time cardiac performance assessment and prediction of intraoperative cardiac impairment.
  • CPI may serve as a valuable tool analogous to ventriculo-arterial coupling parameters in surgical settings.