Room-Temperature Optical Detection of 14CO2 below the Natural Abundance with Two-Color Cavity Ring-Down Spectroscopy
1Center for Accelerator Mass Spectrometry, Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, United States.
ACS Sensors
|October 31, 2022
Summary
A new spectroscopy method detects radiocarbon (14C) in CO2 samples with high accuracy at room temperature. This breakthrough simplifies radiocarbon detection, enabling wider scientific applications.
Area of Science:
- Analytical Chemistry
- Spectroscopy
- Environmental Science
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
1.2K
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.2K
Double Resonance Techniques: Overview
265
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
265
Atomic Emission Spectroscopy: Instrumentation
567
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
567
Atomic Absorption Spectroscopy: Instrumentation
850
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
850
Atomic Emission Spectroscopy: Lab
224
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
224
Carbon-13 (¹³C) NMR: Overview
6.0K
Carbon-13 is a naturally occurring NMR-active isotope of carbon with a low natural abundance of 1.1%. In contrast, carbon-12 is the most abundant isotope of carbon with zero nuclear spin. Therefore, it is NMR inactive. The gyromagnetic ratio of carbon-13 is smaller than that of protons. As a result, carbon-13 resonance is about 6000 times weaker than proton resonance. For a given magnetic field strength, the resonance frequency of carbon-13 is about one-fourth of the resonance frequency for...
6.0K